Hose blockage, How to check and clear hose blockages – GE 106585 User Manual

Page 9

Advertising
background image

How to Check and Clear Hose Blockages

Low suction or poor pickup may be due to a blockage in the vacuum cleaner.

1. Remove hose from hose retainer and check suction at

end of hose - if little or no suction, check dust cup. Empty
if needed. If no improvement, proceed to step 2.

CAUTION:

Turn off the switch and unplug the electrical cord
before clearing hose.

2. Remove electrical cord from cord hooks. Disconnect the

clear tube by turning quarter turn fastener to the right
to release, then lift away from cleaner.

Check for any obstructions that may be in the tube. Any
obstructions can be removed by using a blunt instrument
to clear the tube.

3. To completely release hose from the unit, remove two

screws.

Any obstructions can be removed by using a blunt
instrument to clear the hose. Flexing the hose may help
loosen the blockage.

After clearing blockage, reverse above steps to reassemble
unit.

2. Disconnect clear tube.

1. Remove hose from hose retainer and

check suction at end of hose.

3. Release hose from unit.

1

9

Hose
Retainer

Clear
Tube

2

Quarter

Turn

Fastener

3

Two Screws

Electrical
Cord

Advertising
This manual is related to the following products: