Garmin Radome Installation Instructions

3

Installation Procedures

The following order of mounting the radome and attaching the power and network cables may vary depending on the installation location and

mount used.

Mounting the Radome

1. When a suitable mounting location is determined, verify that the mounting hole locations are aligned fore and aft, and use the included

mounting template or reference Figure 1 to drill four 9.5 mm (

3

/

8

") mounting holes. (This step is not necessary if you are using a pre-drilled

Garmin compatible or Raymarine

®

mount.)

2. Align the notch and locking ring on the power cable to the power connector. Press the 2-pin power cable to the power connector and the RJ-

45 marine network cable to the RJ-45 socket (Figure 2). Turn the power cable locking ring clockwise until it stops. Tighten the RJ-45 locking

ring clockwise until it is firmly sealed.

3. The power and network cables may be pressed into any of the five guide grooves molded into the bottom of the radome case and secured

under the cable hold-down plate (Figure 2). Avoid excessive bending or twisting of the cables. See the following “Cable Runs” section for

more information.

4. Position the radome on the mounting surface with the triangular mark on the case aligned to the front of the vessel. Apply a bead of marine

sealant around each of the mounting holes on the mounting surface.

5. Apply the included anti-seize compound to the threads of the four M8 x 1.25 x 60 threaded rods.
6. Install the four (4) M8 x 1.25 x 60 threaded rods into the mounting holes on the bottom of the radome. There should be no more than 50 mm

± 1mm (2") extruding from the radome when they are installed properly.

7. Fasten the radome to the mounting surface using the M8 x 1.25 x 60 threaded rods (installed in the previous step), spring washers, flat

washers, and M8 Hex nuts as shown in Figure 3.

The nuts should be torqued to between 13.7-18.6 N m (10-14 lb ft).

Note: The supplied M8 x 1.25 x 60 threaded rods can be used on mounting thicknesses of 5-30 mm (

3

/

16

" - 1

3

/

16

") (recommended). For surfaces over

30 mm (1

3

/

16

"), locally supplied longer threaded rods are needed.

Wire Gauge Table

Figure 1

141.5 mm

(5 /

16

")

"

9.5 mm

(

3

/

8

")

"

233 mm

(9

5

/

32

")

"

Ship's Bow

Distance

Gauge

2 meters (6

1

/

2

ft)

16 AWG

4 meters (13 ft)

14 AWG

6 meters (19 ft)

12 AWG

Figure 2

Mounting

holes

Power

connector

Network

connector

Cable routing

options

Plate

Mounting

bracket

Flat

washer

Spring

washer
M8 x 60

threaded

rod

Radome

M8 nut

Figure 3

Advertising