Performance Charts

312877G

21

Performance Charts

Test Conditions: Pump tested in water with inlet submerged.

0

5

10

15

20

25

30

35

40

45

50

(19) (38) (57) (76) (95) (114) (133) (152) (170) (189)

A

B

C

D

How to Read the Charts

1. Locate fluid flow rate along

bottom of chart.

2. Follow vertical line up to

intersection with selected

operating air pressure

curve.

3. Follow left to scale to read

fluid outlet pressure

(top chart) or

air consumption

(bottom chart).

0

5

10

15

20

25

30

35

40

45

50

(19) (38) (57) (76) (95) (114) (133) (152) (170) (189)

Fluid Flow — gpm (lpm)

20

40

60

80

(0.56)

(1.12)

(1.68)

(2.24)

A

B

C

D

0

0

20

40

60

80

100

120

(0.14, 1.4)

(0.28, 2.8)

(0.41, 4.1)

(0.55, 5.5)

(0.7, 7.0)

(0.83. 8.3)

Fluid Flow — gpm (lpm)

Air

Con

sumpt

ion

- sc

fm

(c

ubic

met

ers

/min.)

Operating Air Pressure

A

125 psi (0.83 MPa, 8.3 bar)

B

100 psi (0.7 MPa, 7.0 bar)

C

70 psi (0.48 MPa, 4.8 bar)

D

40 psi (0.28 MPa, 2.8 bar)

Fl

ui

d

Pr

es

su

re

- p

si

(M

Pa

, b

ar

)

Fluid Pressure

Air Consumption

Advertising