Installation, Tighten fasteners before setup, Warning – Graco HUSKY 312877C User Manual

Page 6

Advertising
background image

Installation

6

312877G

Installation

The Typical Installations shown in F

IG

. 3 and

F

IG

. 4 are only guides for selecting and install-

ing system components. Contact your Graco

distributor for assistance in planning a system

to suit your needs.

Tighten Fasteners Before Setup

Before using the pump for the first time, check

and retorque all external fasteners. Follow

Torque Instructions, page 16.

PRESSURIZED ALUMINUM PARTS HAZARD

Use of fluids that are incompatible with aluminum in pressurized equipment can cause

serious chemical reaction and equipment rupture. Failure to follow this warning can

result in death, serious injury, or property damage.

Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated

hydrocarbon solvents or fluids containing such solvents.

Many other fluids may contain chemicals that can react with aluminum. Contact

your material supplier for compatibility.

PLASTIC PARTS CLEANING SOLVENT HAZARD

Use only compatible water-based solvents to clean plastic structural or pressure-con-

taining parts. Many solvents can degrade plastic parts and cause them to fail, which

could cause serious injury or property damage. See

Technical Data in this and all

other equipment instruction manuals. Read fluid and solvent manufacturer’s warnings.
TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on

skin, inhaled, or swallowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Route exhaust away from work area. If diaphragm ruptures, fluid may be exhausted

with air.

Store hazardous fluid in approved containers, and dispose of it according to appli-

cable guidelines.

BURN HAZARD

Equipment surfaces and fluid that’s heated can become very hot during operation. To

avoid severe burns:

Do not touch hot fluid or equipment.

PERSONAL PROTECTIVE EQUIPMENT

You must wear appropriate protective equipment when operating, servicing, or when in

the operating area of the equipment to help protect you from serious injury, including

eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes

but is not limited to:

Clothing and respirator as recommended by the fluid and solvent manufacturer

Protective eyewear, gloves, and hearing protection

WARNING

Advertising