11

Service

Torque Table

Find the proper torque specifications for your surge suppressor unit in the table below. These are the torques to
which the clamp band, ring flange, or bolts in bolted units need to be tightened.

KEY:

plastic = polypropylene or acetal
metal = stainless steel
rubber = fluoroelastomer or Buna–N

Model

Bladder
Material

Housing

Material

Type of Clamp

Torque

Husky 2000

rubber

plastic

clamp band

45 to 55 in-lb (5.1 to 6.2 N-m)

Husky 2000

rubber

plastic

ring flange

65 to 70 in-lb (7.3 to 7.9 N-m)

Husky 2000

PTFE

plastic

ring flange

90 to 105 in-lb (10.2 to 11.9 N-m)

Husky 2000

rubber

metal and plastic

clamp band

30 to 40 in-lb (3.4 to 4.5 N-m)

Husky 2000

rubber

metal and plastic

ring flange

80 to 85 in-lb (9.0 to 9.6 N-m)

Husky 2000

PTFE

metal and plastic

ring flange

90 to 95 in-lb (10.2 to10.7 N-m)

Husky 2000

rubber

metal

bolted unit

120 to 130 in-lb (13.6 to 14.7 N-m)

Husky 2000

PTFE

metal

bolted unit

145 to 150 in-lb (16.4 to 16.9 N-m)

Husky 750

rubber

plastic

clamp band

40 to 45 in-lb (4.5 to 5.1 N-m)

Husky 750

rubber

plastic

ring flange

50 to 55 in-lb (5.6 to 6.2 N-m)

Husky 750

PTFE

plastic

clamp band

80 to 85 in-lb (6.8 to 9.6 N-m)

Husky 750

PTFE

plastic

ring flange

85 to 90 in-lb (9.6 to 10.2 N-m)

Husky 750

rubber

metal

bolted unit

80 to 85 in-lb (9.0 to 9.6 N-m)

Husky 750

PTFE

metal

bolted unit

110 to 115 in-lb (12.4 to 13.0 N-m)