Operation, Warning, Automatic husky 750 – Graco Inc. Husky 239126 User Manual

Page 7: Automatic husky 2000, Manual husky 750, Manual husky 2000

Advertising
background image

308703

7

Operation

Pressure Relief Procedure

WARNING

PRESSURIZED EQUIPMENT HAZARD
The equipment stays pressurized until pressure is
manually relieved. To reduce the risk of serious
injury from pressurized fluid, accidental spray from
the dispensing device, or splashing fluid, follow this
procedure whenever you

D

Are instructed to relieve pressure

D

Stop pumping

D

Check, clean, or service any system equipment

D

Install or clean fluid nozzles

1.

Stop pumping, and shut off the air to the pump.

2.

Relieve pressure in the surge suppressor as
follows:

D

For automatic surge suppressors, remove the
air pressure gauge, and allow any residual air
pressure to escape.

D

For manual surge suppressors, adjust the
regulator to relieve the air pressure by dialing
down the pressure.

WARNING

TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can
cause serious injury or death if splashed
in the eyes or on the skin, inhaled, or
swallowed.

D

Read TOXIC FLUID HAZARD on page 3.

D

Use fluids and solvents which are compatible
with the equipment wetted parts. Refer to the
Technical Data section of all equipment manu-
als. Read the fluid and solvent manufacturer’s
warnings.

WARNING

FIRE AND EXPLOSION HAZARD

Charge the surge suppressor with
compressed air or nitrogen only. Do not
use oxygen.

Never pump flammable fluids with
polypropylene units.

Charging the surge suppressor with oxygen or
pumping flammable fluids with polypropylene units
could cause a fire or an explosion.

Minimum and Maximum Operating
Temperatures

Find the minimum and maximum operating tempera-
tures for your surge suppressor unit in the list below.
These temperature limits are stated at zero gauge
pressure.

Automatic Husky 750

239095

10

_

to 180

_

F (–12

_

to 82

_

C)

239096

32

_

to 175

_

F (0

_

to 79

_

C)

239121

40

_

to 175

_

F (4

_

to 79

_

C)

239122

32

_

to 175

_

F (0

_

to 79

_

C)

239123

40

_

to 220

_

F (4

_

to 104

_

C)

239124

–10

_

to 350

_

F (–23

_

to 176

_

C)

Automatic Husky 2000

239092

32

_

to 175

_

F (0

_

to 79

_

C)

239093

32

_

to 175

_

F (0

_

to 79

_

C)

239126

40

_

to 175

_

F (4

_

to 79

_

C)

239127

32

_

to 175

_

F (0

_

to 79

_

C)

239128

40

_

to 175

_

F (4

_

to 79

_

C)

Manual Husky 750

239090

10

_

to 180

_

F (–12

_

to 82

_

C)

239091

32

_

to 175

_

F (0

_

to 79

_

C)

239129

40

_

to 175

_

F (4

_

to 79

_

C)

239130

32

_

to 175

_

F (0

_

to 79

_

C)

239131

40

_

to 220

_

F (4

_

to 104

_

C)

239132

–10

_

to 350

_

F (–23

_

to 176

_

C)

Manual Husky 2000

239087

32

_

to 175

_

F (0

_

to 79

_

C)

239088

32

_

to 175

_

F (0

_

to 79

_

C)

239134

40

_

to 175

_

F (4

_

to 79

_

C)

239135

32

_

to 175

_

F (0

_

to 79

_

C)

239136

40

_

to 175

_

F (4

_

to 79

_

C)

Advertising