Electrocution hazards, Tip-over hazards – Genie TZ-50 User Manual

Page 4

Advertising
background image

2

Genie TZ-50

Part No. 114164

Operator's Manual

Second Edition • First Printing

SAFETY RULES

Electrocution Hazards

This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.

Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.

Voltage

Minimum Safe

Phase to Phase

Approach Distance

Feet

Meters

0 to 300V

Avoid Contact

300V to 50KV

10

3.05

50KV to 200KV

15

4.60

200KV to 350KV

20

6.10

350KV to 500KV

25

7.62

500KV to 750KV

35

10.67

750KV to 1000KV

45

13.72

Allow for platform movement, electrical line sway
or sag and beware of strong or gusty winds.

Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.

Do not operate the machine during lightning or
storms.

Do not use the machine as a ground for welding.

Tip-over Hazards

Occupants, equipment and materials shall not
exceed the maximum platform capacity.

Maximum capacity

ANSI and CSA models

500 lbs

227 kg

CE and Australia models

440 lbs

200 kg

Maximum occupants

2

Do not raise the boom unless the machine is level.

Do not set the machine up on a surface where it
cannot be leveled using only the outriggers.

Do not raise the boom unless all four outriggers
are lowered, the footpads are in firm contact with
the ground and the machine is level.

Do not set the machine up unless it is on a firm
surface. Avoid drop-offs, holes, unstable or
slippery surfaces and other possible hazardous
conditions.

Do not move the machine when the boom is
raised.

Do not adjust or stow the outriggers when the
boom is raised.