Electrical connection – GE JN327 EN User Manual

Page 8

Advertising
background image

B. ELECTRICAL CONNECTION

1. Be sure the power supply is disconnected before

making electrical connections.

2. Remove the connection box cover located on the

left side of the fan unit.

3. Attach the power supply through the knockout hole

in the back or top of the hood.

4. Connect the colored incoming power supply

lead to the stripped black lead and connect the
incoming white neutral lead to the stripped white
lead in the connection box as shown in Figs. 12
and 13. Make connections in the hood in
accordance with local codes.

5. A ground lug is provided for proper grounding of the

hood frame. It is recommended that the hood frame
be grounded in accordance with National Electrical
Code and local codes (see Figs. 12 and 13).

6. All electrical connections should be inspected

carefully before the power is turned on to make
certain that none have come loose during shipment.

7. Reinstall the connection box cover.

8. Install a lamp (not supplied with hood in the socket).

(CAUTION: Maximum wattage on the lamp
should not exceed 60 watts.)

WARNING: IMPROPER CONNECTION
OF ALUMINUM HOUSE WIRING TO
THESE COPPER LEADS CAN RESULT
IN A SERIOUS PROBLEM. USE ONLY
CONNECTORS DESIGNED FOR JOINING
COPPER TO ALUMINUM AND FOLLOW
THE MANUFACTURER’S RECOMMENDED
PROCEDURE CLOSELY.

8

FIGURE 12

FIGURE 13

Top of hood

Cut off excess wire length so wires will
be easy to position under cover.

Knockout
plate

Power
supply

Power supply
connection
box cover

Mounting screw

Ground lug

(ground per para B3 colored leads)

Ground

(green)

lead

White
lead

Wire nuts

Connection
box cover
mounting
screw

Wire nuts

Power supply

Grounding lug

Ground
wire

Connection
box cover

White
leads

Colored leads

Advertising