Pump Unit: The Pump unit will need to be mounted within at least 20” of the ECU. It will need to be mounted

in a horizontal position to a solid surface. Do not mount the pump vertical with the pump end down, air gets

trapped in the pump head end and it will not work correctly. Do not lengthen or splice the #5 wire or the orange

and black power wires. See page 18

Unbalanced Cylinder Kit: You will need to determine whether the cylinders on the boat are either Balanced or Unbalanced.

If the cylinder or cylinders are Unbalanced then an Unbalanced Kit will need to be installed on the pump between the pump

and the manifold.

Deckmount: The deckmount should be mounted on the dash near the helm. See page 24

.

Electronic Control Unit (ECU): The ECU will need to be mounted within 20” of the pump unit. Most all components in

the system connect to this unit, so considerations will need to be made due to access and cable lengths. (Extension cables

are available.) Note: Make note of Serial #’s and record them in the Manual. See page 18.

Compass Ball: The Compass Ball needs to be located in the forward 1/2 of the boat. Mount it in a location where it will

not be disturbed or damaged, and protected against wash down or submergence. Mount the Compass Ball no higher than

10’ above the waterline. The Compass may be extended using extensions available from TR-1. The Compass ball will need

to be accessed for the Warning Horn, GPS and Shadow Drive valve connections. When making those connections, use the

blue connectors provided in the accessory pack. See page 19

Tach Sensor Cables: You will need to splice the end of the tach sensor lead to the tach sensor wire from your motor. You

may need to refer to a wiring diagram of your motor. The other wire connects to a clean ground. The other end will plug

into the ECU at connection # 2 as per wiring diagram. The tach may be extended using shielded twisted pair wire. See page

26 & 27.

Shadow Drive Hydraulic Valve/Sensor: The Shadow Drive is an electronic bi-directional valve. It will need to be

mounted as shown in the system layout and can be extended using 18-22 gauge wire to make the electrical connections.

It needs to be mounted closer to the helm than to the pump unit, and will need to be mounted horizontally, and as level

as possible. (In a dual station helm, mount closer to and below the lowest helm.) Do not mount the Shadow Drive Valve

within 12” of any magnetic interference such as speakers or drive motors. Do Not Install valve directly to the fittings

at the back of the helm. Be sure to install a length of hose between the fitting at the helm and the Shadow Drive valve. TR-1

recommends a length of hose between Shadow Drive and any Tee. In a single helm installation, do not place a tee in the

line between the helm and Shadow Drive Valve. This is very important for the Shadow Drive feature to work correctly.

Air can and will get trapped in the valve during installation and bleeding. It’s very important to get all the air out of the

Hydraulic Lines, Helms, Pump, Cylinder (s) and The Shadow Drive valve. See page 21 & 22.

Mounting Considerations, Protection, Hydraulic Connections, Magnetic

Environment, System Maintenance

BALANCED CYLINDER

Unbalanced Cyl.

Unbalanced Cyl.

�������� ������

These examples are cylinders that Do Not

require an unbalanced kit

Unbalanced Cyl.

Unbalanced Cyl.

Unbalanced Cyl.

���������� ������

These are examples of cylinders that

Need an unbalanced kit

Unbalanced Kit

Unbalanced Cyl.

Unbalanced Cyl.

Advertising