Garmin GLADIATOR TR-1 User Manual

Page 22

Advertising
background image

22

23

The shadow drive valve must be mounted in a

level horizontal position using the cable ties

& mounts with screws included in installation

pack It should be mounted in-line between

the helm and the hydraulic pump and motor.

It must be mounted lower than the helm, but

higher than the pump.

Electrical Connections:

Connect the red and black wires from the Shadow Drive Valve

to the Brown and Green wires located at the Compass Ball. See

page 8. Use the blue connectors in the accessory pack to make

those connections. See Fig 18-20 for instructions on blue

connectors. (Page 19).The wires can be extended using 18-22

gauge wire.

Shadow Drive Valve/Sensor: The Shadow Drive is an electronic bi-directional valve. Install it as shown in the system

layout.Install it horizontally, as level as possible, and mount the valve lower than the helm. Avoid any loops in the

hydraulic lines, air may get trapped and cause the autopilot not to work properly. It needs to be mounted closer to

the helm than to the pump unit.

Do Not

mount the Shadow Drive Valve within 12” of any magnetic interference such as speakers or pump motors.

Do Not Install valve directly to the fi ttings at the back of the helm, it will damage the helm. Be sure to install a length of

hose between the fi tting at the helm and the Shadow Drive valve. TR-1 recommends a length of hose between Shadow Drive

and any Tee. In a single helm installation, do not place a tee in the line between the helm and Shadow Drive Valve.

This is very important for the Shadow Drive feature to work correctly. Air can and will get trapped in the valve during

installation and bleeding. It’s very important to get all the air out of the Hydraulic Lines, Helms, Pump, Cylinder(s) and

The Shadow Drive valve.

Do Not Install

the Shadow Drive in the return or compensating line.

Do Not

use tefl on tape on hydraulic fi ttings. However, for a leak free hydraulic system,

we do advise you to use an appropriate thread sealant such as, Loctite “Pro Lock”

multipurpose anacrobic gel, part number 51604, or equivalent on all pipe threads.

To pump &

Cylinder

To Helm

(Close up view)

Compass

Ball

Shadow Drive

# 4

Red

Black

Brown

Green

Installation Of Shadow Drive Valve (Single Helm Station)

BALANCED CYLINDER

Return line

*Shadow Drive

HELM

P= Port

R= Return

S= Starboard

P

R

S

Port Fitting

Starboard Fitting

Pump &

Motor

Advertising