One-piece door – Genie TRILOG 3064H User Manual

Page 18

Advertising
background image

• With the door closed, pull

release handle

DOWN and let go to release door carriage

assembly from drive system.

• Raise door manually approximately 3’- 4’ and

release.

– Door should remain stationary or move very

slightly.

– If door moves quickly, CONTACT A TRAINED

DOOR SYSTEM TECHNICIAN.

• Close the door.
• Verify shuttle arm is in the up position.

(refer to page 19)

– Operate door using remote or wall console.

– Door will re-attach itself to carriage assembly.

©2010 The Genie Company

12/2010

18

WARNING

• Garage door hardware (springs, cables, brackets,

pulleys, etc.) are under extreme pressure and

tension.

DO NOT attempt to repair or adjust door

springs or any hardware, and DO NOT OPERATE

garage door automatically or manually if door

is improperly balanced or springs are broken.

CONTACT A TRAINED DOOR SYSTEM

TECHNICIAN.

ROUTINE MONTHLY MAINTENANCE

Basic monthly maintenance tasks.

• Safe-T-Beam® System Check
• Door balance
• Contact reverse

Instructions for these tasks and others are found on

the following pages.

DOOR BALANCE (SPRING TENSION)

3’ - 4’

Sectional Door

3’ - 4’

One-Piece Door

FIG. 6-1 Door balance

WARNING

Use wall console supplied with opener. Other

approved wall consoles may be available.

Unapproved or incompatible wall consoles can

cause the opener to operate unexpectedly.

Safe-T-Beam® (STB) SYSTEM CHECK

• STB Red and Green LEDs ON steady, system OK
• STB Red LED flashes

– Check for obstruction

– Check alignment

– Verify wire routing from

STBs to STB connection in

powerhead

– Check for signal interference

from another Safe-T-Beam®

unit

• No STB Red or Green LED displayed

– Check wiring and wire connections

STB

BWC

IWC

NOT

USED

NOT

USED

NOT

USED

NOT

USED

FROM STBs

FROM WALL

CONSOLE

FIG. 6-2 2 x 4 under center of door opening

CONTACT REVERSE TEST (Monthly test)

The Force and Limit settings MUST be

COMPLETED before testing. (See pages 6-7)
1.
Test.

• Open garage door using wall console.

– Place a 2" x 4" board (laid flat) under center of

garage door opening (Fig. 6-2).

• Close garage door using wall console.

• When door contacts board, the door must

stop (within 2 seconds) and reverse direction

returning to open position.

2. Adjustment.

• If the door:

– Stops before it contacts the 2 x 4 board, it may

simply be responding to an improperly set

down limit. Return to pages 6-7 and repeat

steps 1 through 10 to correct down limit.

– Stops after contacting the 2 x 4 board and

does not reverse, it may need an adjustment

to the down limit. Return to pages 6-7 and

repeat steps 1 through 10 to correct down

limit.

• Test again. Repeat as necessary until door

reverses upon contacting board.

Advertising