Electrical supply, Electrical supply –17 – GE 2800 User Manual

Page 14

Advertising
background image

Installation Instructions

HOW TO CONNECT

IF USING AN ELECTRICAL
SUBBASE

1 Remove the room cabinet.
2 Connect to electrical power.
3 See the special instructions below for applicable

supply voltages.

4 Reinstall the room cabinet.

Tandem
15 Amp.

230/208 volt receptacle configuration.

Perpendicular

20 Amp.

Large Tandem

30 Amp.

Order Kit RAK4002A for 230/208 volt direct
connection.

Power cords may include an arc fault interruption or
a leakage current detection interruption device. A
test and reset button is provided on the plug case or
the inline case. The device should be tested on a
periodic basis by first pressing the TEST button and
then the RESET button. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the Zoneline and contact a
qualified service technician.

230/208 volt models may be installed using one of
the following electrical subbases:

*Not approved for use on 7000 BTU models.

Electrical subbases provide an enclosure for direct
connection or enclosed receptacles. The subbase kit
includes the power cord.

The instructions provided with the selected subbase kit
must be carefully followed. It is the responsibility of the
installer to ensure the connection of components is
done in accordance with these instructions and all
electrical codes.

Branch Circuit and

Proper GE

Unit Amperage Rating

Subbase Kit

15

RAK204D15P

20

RAK204D20P

30

RAK204D30P*

A power supply kit must be used to supply power to the
Zoneline unit. The appropriate kit is determined by the
voltage, the means of electrical connection and the
amperage of the branch circuit.

Connections of 208 or 230 volt circuits may be with a
power supply kit or a junction box kit.

All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations. Local codes may require
the use of an arc fault or leakage current detection
device on the power cord. Be sure to select the
correct cord for your installation.

Power supply kit

Branch Circuit and

Proper GE Power Cord

Unit Amperage Rating

with LCDI Device

15

RAK3153

20

RAK3203

30

RAK3303*

14

230/208 VOLT ELECTRICAL SUPPLY

*Not approved for use on 7000 BTU models.

Advertising