Troubleshooting Tips
Save time and money! Review the charts on the following
pages first and you may not need to call for service.

Problem

Possible Causes

What To Do

Zoneline does

The unit is

• Make sure the Zoneline plug is pushed completely

not start

unplugged.

into the outlet.

The power cord is not

• Remove the room cabinet and make sure that the

firmly attached.

yellow connector on the end of the power cord is
firmly engaged.

The fuse is blown/circuit

• Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

The unit is waiting for

• This is normal. The Zoneline will start again after

the compressor overload

it resets.

protector to reset.

Power failure.

• If power failure occurs, set the mode control to STOP.

When power is restored, set the mode control to the
desired setting.

• There is a protective time delay (up to 3 minutes) to

prevent tripping of the compressor overload. For this
reason, the unit may not start normal heating or cooling
for 3 minutes after it is turned back on.

The current interrupter

• Press the RESET button located on the power cord plug

device is tripped.

or the box near the plug.

• If the RESET button will not stay engaged, discontinue use

of the Zoneline and contact a qualified service technician.

Zoneline does not cool

Indoor airflow

• Make sure there are no curtains, blinds or furniture

or heat as it should

is restricted.

blocking the front of the Zoneline.

Outdoor airflow is

• Make sure the rear grille is not restricted. This can

restricted or recirculated.

cause the unit to cycle off due to the compressor
overload protector.

• Outdoor grille must have a minimum of 65% free area.

Non-GE grilles may be too restrictive for proper
performance. Consult your salesperson for assistance.

The temp control may

• Turn the control to a lower or higher setting.

not be set properly.

NOTE: The temperature limiter may be limiting the temperature range.

The air filter is dirty.

• Clean the filter at least every 30 days.

See the Operating Instructions section.

The room may have

• When the Zoneline is first turned on you need to

been hot or cold.

allow time for the room to cool down or warm up.

Outdoor air is

• Set the vent control to the closed position.

entering the room.

Burning odor at the start

Dust is on the surface

• This can cause a “burning” odor at the beginning of

of heating operation

of the heating element.

the heating operation. This odor should quickly fade.