The Standard Installation of this Drop-In Range
is to hang by the countertop on the side metal
flanges under cooktop. This Range must not
be installed on a base or sub structure
(2”x 4” support).

If the construction of your cabinet cannot
provide a 1/4” flat area at the back of the
countertop opening, consider changing the
countertop to accommodate this dimension.

Center the 30” wide opening over the
adjacent cabinets and mark with a straight
edge.

Using a straight edge, mark the back line
at 23-3/16” from the front edge of the
counter.

Be careful not to damage the adjacent
cabinets while cutting the countertop.

Remove countertop raised edge, if
incorporated. (See illustration on page 4.)

4

3

2

1

PREPARE TO INSTALL THE RANGE

STANDARD INSTALLATION

Wall

1/4” min.

flat

23-3/16”

9/16” min.

flat

9/16” min.

flat

29-15/16”– 30-1/16”

smooth cut

25”

typically

1/4”

R

Flat

area

Countertop

Range support

Braces secured between the
underside of the countertop and
the cabinet if required to obtain
1-1/4” minimum thickness (two
sides)