Installation – Greenheck Fan Grease Grabber Power Play Kitchen Exhaust Pollution Control System 474754 User Manual

Page 4

Advertising
background image

4

Grease Grabber™ Power Play Kitchen Exhaust Pollution Control System

Installation

Remote Mounted Detergent Dispenser
A 55 gallon remote mounted detergent dispenser
is included as part of the electrostatic collector
self-wash system. Included as part of the 55 gallon
dispenser assembly is a solenoid valve, pressure
gauge, ball valve, y strainer, and backflow preventer.
The detergent dispenser must be mounted indoors
on a solid, level foundation, as close to the cabinet
assembly as possible, and in a freeze protected
location accessible to maintenance personnel. The
1/2 inch line from the detergent dispenser must be
connected to the water supply line within 5 feet of
the precipitator. Refer to the PLUMBING section for
details on plumbing connections.

Remote Mounted System Control Panel and
Power Pack (2 pieces)
The system control panel allows the user to interface
with the unit and controls operation as well as
monitors wash and other functions. The Power
Pack contains a power transformer and works in
conjunction with the System Control Panel and the
unit’s high voltage ionizer cells. The System Control
Panel should be mounted in an area easily accessible
to daily operational staff. The Power Pack should be
mounted as close as possible to the System Control
Panel and both should be mounted as close to the
cabinet assembly as possible. Allow adequate room
from the face of the panels for door swing clearance
and servicing.

Rigging/Placing Equipment
1. The unit is furnished with lifting lugs at the four

corners and along the length as necessary.

2. Lift into place using all the lifting lugs.
3. Field weight will vary depending upon final

selections such as fan type, accessories, etc.
Approximate weights are shown in the table below.

4. The unit can be positioned on a base or curb

suitable for this purpose.

5. The unit must be anchored to its base/curb.
6. Alternatively, the unit may be suspended from

an adequate overhead structure, using suitable
undercarriage or hanging rods (by others). If the
unit is suspended by hanging rods, minimum
1/2 inch (12.7 mm) diameter threaded rod is to be
used. All hanger brackets/lifting lugs must be used
to ensure proper support of the unit. The unit must
also be hung level to ensure proper operation.

7. A service clearance of 42 inches must be provided

on the access door side of the unit.

8. A minimum 18 inch clearance must be maintained

between this unit and any combustible material.

Unit Size

Approximate

Weight (lbs)

Approximate

Weight (kg)

02-03

3100

1409

02-04

3620

1645

02-05

4025

1830

02-06

4280

1945

04-03

4000

1818

04-04

4580

2082

04-05

5200

2364

04-06

5700

2591

04-07

6420

2918

04-08

7080

3218

04-09

7560

3436

06-03

5200

2364

06-04

6140

2791

06-05

6800

3091

06-06

7325

3330

06-07

8275

3761

06-08

8800

4000

06-09

9510

4350

Filter Quantities

Unit

Size

Safety Filter

Quantity

(2 ft. tall x 2 ft. wide)

Safety Filter

Quantity

(2 ft. tall x 1 ft. wide)

02-03

1

1

02-04

2

0

02-05

2

1

02-06

3

0

04-03

2

2

04-04

4

0

04-05

4

2

04-06

6

0

04-07

6

2

04-08

8

0

04-09

8

2

06-03

3

3

06-04

6

0

06-05

6

3

06-06

9

0

06-07

9

3

06-08

12

0

06-09

12

3

High Voltage Cable
High voltage cable is supplied to connect the ionizer/
collector sections of the precipitator to the ionizer and
collector terminals in the Power Pack. The red cable
(50 ft supplied) is used for the ionizer and the blue
cable (50 ft supplied) is used for the collector. Refer to
the ELECTRICAL section for details on wiring.