Dimensions and specifications installation – Garland CG-60F User Manual

Page 4

Advertising
background image

Part # 4520498 (11/24/08)

Page 4

DIMENSIONS AND SPECIFICATIONS

INSTALLATION

IMPORTANT: The installation must comply with local codes,

or in the absence of local codes, with

CAN/CSA - B149 Installation Code – latest edition or with the

National Fuel Gas Code NFPA 54 ANSI Z223 .1 – latest edition .

All burner adjustments and settings shall be made by a

qualified gas technician .

Serial Plate Location

All burner inputs are shown on the Serial/Rating Plate of

each unit, located on the bottom of the control section near

the front .

When corresponding with the factory or your local

authorized factory service center regarding service problems

or replacement parts, be sure to refer to the particular unit

by the correct model number (including the prefix and suffix

letters and numbers) and the warranty serial number . The

rating plate contains this information .

INSTALLATION NOTES

MINIMUM SUPPLY PRESSURE REQUIRED

ELECTRICAL CHARACTERISTICS

Combustible Wall Clearances

Natural

Propane

Specifications

Sides

Back

7" W .C . (17 .4mbar)

11" W .C . (27 .4mbar)

120 V, Single Phase, 60Hz, 1 amp

6' (1829mm)

power supply cord provided

MANIFOLD PRESSURE REQUIRED,

AFTER BUILT-IN REGULATOR

6" (152mm)

6" (152mm)

3 .5” W .C . (8 .75 mbar)

10” W .C . (25mbar)

IMPORTANT: Unit must be

installed on legs for proper

air circulation . A minimum 4”

(101mm) air space must be

maintained below unit for

required air flow to burners .

Gas Input Ratings shown are for

installations up to 2,000 feet (610mm)

above sea level . BTU input ratings must

be derated for high altitude installations

NOTE: No cord and plug on export

units . Direct connection to junction

box .

VENTILATION

EXPORT VOLTAGES

• Commercial cooking equipment

requires an adequate ventilation system .

Foradditional information, refer to the

National Fire Protection Association’s

Standard NFPA 96 .

NOTE: Export voltages are available

on request .

ENTRY CLEARANCE

Crated

Uncrated

• 220-240 volt, 50 Hz, 0.4 amps, single

phase .

40" (1016mm)

38" (965mm)

INPUT CHART - Natural Or Propane Gas

Model

Number

BTU/

HOUR

Kw

Gas

Inlet

Shipping Weight

LBS .

KGS .

CG-48F

120,000

35 .00

3/4"

625

284

CG-60F

150,000

44 .00

3/4"

765

348

CG-72F

180,000

52 .70

1"

905

411

Advertising
This manual is related to the following products: