Installation continued – Garland CG-60F User Manual

Page 5

Advertising
background image

Part # 4520498 (11/24/08)

Page 5

NOTE: The griddle plate may not rest

evenly on the unit body if the unit is

not properly leveled .

5 . Each caster has a threaded stem

to aid in leveling only . No caster

should be adjusted beyond

a maximum of one-half inch,

(1/2”/13mm) of exposed thread

with the locking nut tight against

the stand leg, as shown .

Clearances

This unit must be installed in accordance with the following

clearances in order to provide proper operation and

servicing of the appliance .

Clearances

Sides

Back

Left

Right

Combustible

6”

(152mm)

6”

(152mm)

6”

(152mm)

Noncombustible

0”

0”

0”

Service

Not Required

Type of Floor or Base

Combustible

Gas Connections

1 . A readily accessible gas shut-off valve is provided on each

unit, attached to the main manifold under the unit . The

gas supply connection must be made with minimum

3/4 inch NPT pipe . Larger than 3/4 inch (19 mm) supply

pipe may be required when a long run of supply pipe

is necessary . Consult the pipe capacity tables in the

installation code .

2. Have a qualified gas technician check the gas pressure

to make certain that the existing gas facilities (meter,

piping, etc .), will deliver the BTU’s of gas required at the

unit, with no more than 1/2 inch (12 mm) water pressure

drop. When checking pressure, be certain that all the

equipment on the same gas line is turned “ON” .

3 . The appliance and its individual shut off valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in

excess of 1/2 PSIG . (3 .45 KPA) .

We suggest installation, maintenance and repairs should be

performed by your local authorized service agency listed in

your information manual pamphlet .

In the event you have any questions concerning the

installation, use, care or service of the product, write or call

our Product Service Department .

This product must be installed by professional personnel as

specified . Garland/U .S . Range products are not approved or

authorized for home or residential use, but are intended for

commercial applications only . Garland / U .S . Range will not

provide service, warranty, maintenance or support of any

kind other than for commercial applications.

General Information

Damage Check: check carton or crate for possible damage

incurred in shipping. After carefully examining, check for

“concealed” damage . Report any damage immediately to

your carrier .

Legs, Casters & Leveling

1 . The unit must be installed on the legs or casters

provided . A minimum 4 inch (101 mm) air space must

be maintained below the unit for required air flow to the

burner systems . Avoid placing any objects under the unit

which could obstruct air flow to the burner systems .

2 . For models equipped with casters,the installation shall be

made with a connector that complies with the Standard

for Connectors for Moveable Gas Appliances, ANSI

Z21 .69/CSA 6 .16, Addenda Z21 .69B-2006/CSA 6 .16B-2006

(or latest edition), and a quick-disconnect device that

complies with the Standard for Quick Disconnects for Use

with Gas Fuel, ANSI Z21 .41/CSA 6 .9, Addenda Z21 .41A-

2005/CSA 6 .16A-2005 (or latest edition) .

3 . Adequate means must be provided to limit movement of

the appliance without depending on the connector and

quick disconnect device or associated piping. This can

be accomplished by attaching restraining chains/cables

from floor or rear wall to rear of unit .

Ensure front casters are kept in the locked position except

when the unit must be moved for cleaning or servicing,

etc .

4 . When the unit is installed in its operating location, level

the unit by adjusting the leveling legs . Use a level across

the front rear, and sides of each unit .

1/2"

(13mm)

MAX

INSTALLATION Continued

Advertising
This manual is related to the following products: