Adjustments continued – Garland CG-60F User Manual

Page 8

Advertising
background image

Part # 4520498 (11/24/08)

Page 8

ADJUSTMENTS Continued

Drawing A

Place the probe

within a

1 1/2 " circle

for maximum

accuracy

5 7/8"

12"

12"

12"

10"

2 . Place the surface temperature probe in the locations

indicated on Diagram A . Watch the amber indicator for

the zone being measured . When the amber indicator

is ON the burner for that zone is on . When the amber

indicator goes OFF note the temperature . The measured

temperature at the time the amber indicator switches off

should be no more than ± 5°F from the set temperature .

If the error is greater than ±5°F, but less than ± 10° F, then

firmly grasp the thermostat dial (be sure to not change

the 360° F setting) and loosen the dial set screw so that

the dial can rotate freely on the thermostat shaft .

Carefully rotate the dial to indicate the temperature

registered by your temperature indicating device and re-

tighten the set screw . Each minor line on the thermostat

dial’s scale is 5°F .

Reposition the dial to the calibration temperature

setting of 360° F . Allow sufficient time for the grill

surface temperature to stabilize and repeat the above

instructions .

If the temperature is greater than ± 10°F, consult a service

technician .

Advertising
This manual is related to the following products: