Installation/operation, Warning – Graco Inc. 235457 User Manual
Page 8
8
308-235
Installation/Operation
How to Check the Gun Diffuser Operation
Check the diffuser operation weekly. The gun diffuser/
seat (2a) breaks up spray and reduces the risk of fluid
injection when the tip is not installed. Perform the test
below. If it fails, replace the entire Needle Kit, Part No.
235–474, as instructed on page 7. Diffuser/seats are
not sold separately since the gun will leak if an old
needle is used with a new diffuser/seat.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 5.
1. Follow the
Pressure Relief Procedure, page 5.
2. Remove the tip guard and spray tip.
3. Start the sprayer and adjust it to the lowest
pressure.
4. Aim the gun into a grounded metal pail while
holding it firmly to the pail. Trigger the gun. If the
fluid emitted
is not diffused into an irregular
stream, replace the entire needle kit immediately.
See Fig. 5.
Fig. 5
2a
How to Flush the Gun.
Always flush the pump and the gun before the fluid
being sprayed can dry in it.
NOTE: If it is available, the flushing procedure
provided in your pump or sprayer manual should be
used instead of this procedure.
WARNING
FIRE AND EXPLOSION HAZARD
Static sparking and splashing may cause
fire, explosion and serious injury. To
reduce static sparking and splashing,
always remove the spray tip from the gun, and hold
a metal part of the gun firmly to the side of a
grounded metal pail when flushing.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 5.
1. Follow the
Pressure Relief Procedure, page 5.
2. Remove the tip guard and spray tip. Soak and
clean the parts.
3. Put the pump intake in a grounded pail of water or
solvent.
4. Start the pump at its lowest pressure.
5. Trigger the gun into the original pail. When solvent
appears, release the trigger.
6. Now trigger the gun into the solvent pail. Circulate
the fluid until the system is thoroughly flushed.
7. Follow the
Pressure Relief Procedure, page 5.