Model g0453z/g0454z (Mfg. 1/09+)

220v Single-Phase

Operation

full Load Amperage Draw

this machine draws the following amps under
maximum load:

g0453z Amp draw ............................... 15 Amps
g0454z Amp draw................................25 Amps

Power Supply Circuit Requirements

the power supply circuit for your machine Must
be grounded and rated for the amperage given
below. never replace a circuit breaker on an exist-
ing circuit with one of higher amperage without
consulting a qualified electrician to ensure compli-
ance with wiring codes.

If you are unsure about

the wiring codes in your area or you plan to

connect your machine to a shared circuit, con-

sult a qualified electrician.

g0453z Minimum Circuit size ..............20 Amps
g0454z Minimum Circuit size ...............30 Amps

SECTION 2: CIRCUIT REQUIREMENTS

Serious personal injury could occur if you

connect the machine to power before com-

pleting the setup process. DO NOT connect

the machine to the power until instructed

later in this manual.

Electrocution or fire could

result if machine is not

grounded and installed in

compliance with electrical

codes. Compliance MUST

be verified by a qualified

electrician!

Power Connection Device

the type of plug required to connect your machine
to power depends on the type of service you cur-
rently have or plan to install. We recommend
using the plugs shown in

figure 3.

Extension Cords

using extension cords may reduce the life of the
motor. instead, place the machine near a power
source. if you must use an extension cord:

Model g0453z: use at least a 12 gauge cord
that does not exceed 50 feet in length.

Model g0454z: use at least a 10 gauge cord
that does not exceed 50 feet in length.

Ensure that the extension cord contains a
ground wire and plug pin.

A qualified electrician Must size cords over
50 feet long to prevent motor damage.

Grounding Prong

Current Carrying Prongs

6-20 PLUG

GROUNDED

6-20 RECEPTACLE

figure 3. recommended connection types.

Grounding Prong

is Hooked

Current Carrying Prongs

L6-30 GROUNDED

LOCKING

RECEPTACLE

L6-30

LOCKING

PLUG

nEMA L6-30

plug & receptacle

for Models g0454z

nEMA 6-20

plug & receptacle

for Models g0453z