ZGU48N6RWSS—48" Professional Gas Cooktop

Dimensions and Specifications (in inches)

Advance Planning:
Refer to dimensional drawings for appropriate
placement and necessary clearances when
planning the installation.

• Cabinetry cannot be installed directly above

the cooktop.

• This cooktop requires the installation of a vent

hood, 30" to 36" above the surface.
–The vent hood must be at least 24" deep.
–The vent hood must be the same width as

the cooktop.

–The vent hood blower should provide at least

800 CFM and up to 1200 CFM.

–Choose a vent hood with 800CFM for best

performance when operating the grill.

• Working areas adjacent to the range should

have 18" minimum clearance between
countertop and cabinet bottom.

• Clearance between cooktop and side wall or

combustible material must be at least 12" on
each side.

• This cooktop requires 8" free space below

the countertop.

• If the cooktop is installed in an island:

–Allow 12" min. clearance at the back to

combustible materials.

–Allow 36" min. above the cooking surface to

combustible materials.

• Installation must conform with local codes. In

the absence of local codes, the gas cooktop
must comply with the National Fuel Gas Code,
ANSI Z223.1, latest edition.

A.G.A. approved

720Dia2

48" Wide Hood

30" Min.

36" Max.

18" Min.

12" Min. to
Combustible
Material
Each Side

36" Min. to
Combustible
Material From
Cooking
Surface

13" Max.

17"

22-3/4" Min.

Electric/Gas

Supply

46-1/8"

7/8"

8"

2-1/2"

2"

Cooking Surface

Low Back

High
Shelf

26-5/8"

10"

2-1/2"

21-1/4"

12"

36" Min.

to Combustibles

Island Trim

12" Min. to Combustibles
Without Backguard

36" Min.

to Combustibles