A) cl ose door tr a vel limit, Pr ogr amming limits & for ce – Genie INTELLIG 3024 User Manual

Page 6

Advertising
background image

©2010 The Genie Company

01/27/2010

6

P

R

O

G

R

A

M

S

ET

+

5 SECS

SET

TING &

TESTING LIMITS AND FOR

CE

T

he OPEN (UP) and CL

OSE (DOWN)

D

o

or Limit positions

ar

e c

ontr

olled b

y mak

ing

adjustments using the panel locat

ed on the bott

om of the po

w

er head

. Begin with

Step 1 and continue through Step 10.

Doo

r

Fo

rc

e

is set during the final Open/Close

c

y

cle of these st

eps

.

T

he po

w

er head will aut

omatically set door speed at slo

w if the

distanc

e betw

een limits is less than 6 f

eet.

A) CL

OSE DOOR

TR

A

VEL LIMIT

NO

TE:

Y

ou can star

t and st

op door

mo

v

ement using either

butt

ons until

d

o

o

r i

s i

n

c

o

rr

e

c

t

open

or closed

position.

W

a

tch door mo

v

e

PR

OGR

AMMING LIMITS & FOR

CE

(C

ontinuing from Installation P

oster

if pro

vided)

1

G

R

A

M

S

E

+

PRESS and HOLD

5

P

R

O

G

R

A

M

S

ET

+

PRESS and HOLD

SEE BO

TH

Blue LEDs

come ON

SEE r

ound

Blue LED

come ON

P

R

O

G

R

A

M

S

ET

SEE r

ound Blue

LED flashing

RELEASE

1

2

3

4

NO

TE:

If one or both LEDs c

ome ON RED at this

time;

Limits pr

ogr

amming menu was not ent

er

ed

pr

operly

.

Y

ou must exit pr

ogr

amming and r

estar

t.

To exit this mode:

A.

P

ress

PROGRAM

S

ET

and r

elease

B.

P

ause

C.

P

ress

PROGRAM

S

ET

and r

elease

D.

P

ause

E.

Begin with St

ep 1 on this page

. Restar

ting at

S

te

p

1

w

il

l r

e

se

t

RED

LEDs t

o

BL

UE

.

PRESS and RELEASE

W

ARNING

Mak

e sur

e door

w

a

y is in vie

w and clear of obstacles

and people to a

v

oid injur

y or damage to pr

oper

ty

.

DO NO

T oper

a

te this unit fr

om w

all c

onsole bef

or

e

LIMIT

S and FORCE ar

e set

. S

e

v

er

e damage to the

opener can

occur

.

Bullet MUST be engaged to carriage BEFORE setting

limits

. S

ee Installa

tion P

oster (if pr

o

vided) or r

ef

er to

pages 12 and 18.

Please not

e that ther

e is a 30 sec

ond timeout

betw

een each

pr

ogr

amming st

ep

.

A pr

ogr

amming timeout during these st

eps has

occur

ed when

tw

o RED flashing LEDs

appear

.

In the ev

ent of a timeout please r

estar

t at St

ep 1.

NOT

CE

O

R

C

M

UC

D

U

O

N

N H

D

T

ra

v

el door to FULL CL

OSED position

RELEASE

PRESS and

RELEASE

SEE long Blue

LED c

ome ON

If RED LED c

omes ON - ST

OP and

exit pr

ogr

amming

.

Advertising