307-809

Maintenance

Air Line Lubricator

Keep properly filled for automatic air motor lubrication.

Air Line Filter

Drain and clean as necessary.

Hydraulic Power Supply Check

Carefully follow the hydraulic power supply manufac-

turer’s recommendations on reservoir and filter clean-

ing, and periodic changes of hydraulic fluid.

Mix Tank Volume

Don’t let the mix tank run dry. When the tank is empty,

the pump demands more power as it tries to suck in

some fluid. This causes the pump to run too fast,

which can seriously damage the pump.

Stop the Pump at the Bottom of Its Stroke

WARNING

To reduce the risk of serious injury whenever you

are instructed to relieve pressure, always follow the

Pressure Relief Procedure on page 12.

Whenever you stop the pump for any reason, relieve

the pressure. Stop the pump on the downstroke,

before the air motor changes over. If the pump is

stopped on the upstroke a pressure relief seat causes

the piston to creep until it reaches the up position.

Following the

Pressure Relief Procedure helps stop

the pump at the bottom of its stroke.

CAUTION

Failure to stop the pump at the bottom of its stroke

allows fluid to dry on the piston rod, which can cause

damage to the throat packings when the pump is

restarted.