Service – Graco HIGH-FLO 220-569 User Manual

Page 19

Advertising
background image

307-809

19

Service

Fig. 5

1

3

2

Lubricate threads.
Torque to 102–109 NSm

(75–80 ft-lb).

Torque to 68–75 NSm

(50–55 ft-lb).

Model 220–569

Senator Pump

Shown

1

3

2

01926

D

B

C

A

J

E

G

F

H

Fig. 6

1

3

2

Model 220–564

President Pump Shown

Lubricate threads.
Torque to 102–109 NSm

(75–80 ft-lb).
Torque to 68–75 NSm

(50–55 ft-lb).

1

3

2

01927

L

G

K

H

E

C

B

D

Model 236–601

Viscount I+ Pump Shown

01928

Fig. 7

1

3

2

Lubricate threads.
Torque to 102–109 NSm

(75–80 ft-lb).
Torque to 68–75 NSm

(50–55 ft-lb).

E

L

C

B

G

K
H

D

1

3

2

01929

Fig. 8

1

3

4

2

Torque to 20–23 NSm

(15–17 ft-lb).
For President Pumps,

install in second hole

from end of coupling (G);

for Viscount Pumps,

use first hole.

Model 220–564

President Pump Shown

Lubricate threads.
Torque to 102–109 NSm

(75–80 ft-lb).
Torque to 68–75 NSm

(50–55 ft-lb).

5

4

5

2

1

3

3

F

H

G

K

M

L

C

B

E

Advertising