Technical Data

5:1 Ratio Quiet Senator Pumps, Models 220–566 and 220–569

Maximum Working Pressure

3.4 MPa, 34 bar (500 psi)

. . . . .

Air Operating Range 0.28–0.7 MPa, 2.8–7 bar (40–100 psi)

.

Air Consumption

See Performance Chart

. . . . . . . . . . . . . . . . .

Continuous Duty Delivery

45.4 liter/min (12 gpm)

. . . . . . . . . . .

Pump Cycles Per Liter (gallon)

1.3 (5.0)

. . . . . . . . . . . . . . . . . .

Maximum Recommended Pump Speed

60 cycles/min

. . . . .

Air Inlet

3/4 npsm(f)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fluid Inlet

1–1/2” npt(f)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fluid Outlet

1” npt

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wetted Parts

Model 220–566

Carbon Steel, Stainless Steel,

. . . . . . . . .

Ultra-High Molecular Weight Polyethylene, Leather, PTFE

r

Model 220–569

Chrome-Plated Stainless Steel,

. . . . . . . .

Ultra-High Molecular Weight Polyethylene, Leather, PTFE

r

0

50

100

150

200

250

300

350

400

450

500

0

2

4

6

8

10

12

14

10

20

30

40

50

60

70

8

15

23

30

38

46

54

GPM

l/min

CPM

50

40

30

20

10

0

1.40

1.12

0.84

0.56

0.28

CFM

m

3

/min

PUMP

OUTLET PRESSURE

AIR CONSUMPTION

A

B

C

A

B

C

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

1.4, 14

0.7, 7

PSI

1.05, 10.5

0.35, 3.5

1.7, 17

2.45, 24.5

MPa, BAR

2.1, 21

2.8, 28

To find Outlet Pressure (MPa/bar/psi) at a specific

delivery (liter/min or gpm) and operating air pressure

(MPa/bar/psi):

1. Locate desired delivery along bottom of chart.

2. Read vertical line up to intersection with

selected fluid outlet pressure curve (black

curves). Curve slopes from left to right.

Follow left to scale and read outlet pressure.

To find Pump Air Consumption (m

3

/min or

CFM/min) at a specific delivery (liter/min or gpm)

and operating air pressure (MPa/bar/psi):

1. Locate desired delivery along bottom of chart.

2. Read vertical line up to intersection with

selected air consumption curve (gray curves).

Curve slopes from right to left. Follow right to

scale and read air consumption.

A 0.7 MPa, 7 bar (100 psi) air pressure

B 0.49 MPa, 4.9 bar (70 psi) air pressure

C 0.28 MPa, 2.8 bar (40 psi) air pressure

3.4, 34