SPECIFICATIONS

GENERATOR

Type ............................................................................. Synchronous
Rotor Insulation ................................................................... Class H
Stator Insulation .................................................................. Class H
Total Harmonic Distortion ......................................................< 3.5%
Telephone Interference Factor (TIF) ..........................................< 50
Alternator Output Leads 3-phase ........................................... 6-wire
Bearings .........................................................................Sealed Ball
Coupling .......................................................................Flexible Disc
Load Capacity (Standby Rating) ..........................................100kW*
*

NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349,

ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural

gas.

Excitation System ............................................................. Brushless
Generator Output Voltage/kW - 60 Hz

kW

Amp CB Size

120/240V, 1-phase, 1.0 pf

100

417

500

120/208V, 3-phase, 0.8 pf

100

347

400

277/480V, 3-phase, 0.8 pf

100

150

200

Generator Locked Rotor KVA Available @ Voltage Dip of 35%
Single-phase or 208 3-phase ........................................... 190 KVA
480V, 3-phase .................................................................. 225 KVA

ENGINE

Make ................................................................................... Generac
Model ...................................................................................... V-type
Cylinders and Arrangement ............................................................ 8
Displacement ....................................................................... 5.4 Liter
Bore ...................................................................................... 3.55 in.
Stroke ................................................................................... 4.17 in.
Compression Ratio ..................................................................9-to-1
Air Intake System ...............................................Naturally Aspirated
Valve Seats ....................................................................... Hardened
Lifter Type .......................................................................... Hydraulic

Engine Parameters
Rated Synchronous RPM ..............................................60 Hz, 3600
HP at rated kW ................................................................60 Hz, 175

Exhaust System
Exhaust Flow at Rated Output 60 Hz .................................. 953 cfm
Exhaust Temperature at Rated Output ................................ 1000° F

Combustion Air Requirements (Natural Gas)
Flow at rated power, 60 Hz ................................................. 325 cfm

Governor
Type .................................................................................. Electronic
Frequency Regulation ...................................................Isochronous
Steady State Regulation ........................................................± 1/2%
Adjustments:
Speed ............................................................................ Selectable

‹

‹

Engine Lubrication System
Type of Oil Pump ...................................................................... Gear
Oil Filter .............................................................Full Flow, Cartridge
Crankcase Oil Capacity ....................................................5 U.S. qts.

COOLING SYSTEM

Type ....................................................................................... Closed
Water Pump .................................................................... Belt Driven
Fan Speed ................................................................................ 1700
Fan Diameter .....................................................................26 inches
Fan Mode ................................................................................ Puller
Air Flow (inlet air including alternator and
combustion air) ........................................................... 4800 ft

3

/min.

Coolant Capacity ........................................................ (4.0 U.S. gal.)
Heat Rejection to Coolant ..........................................376,000 Btu/h
Maximum Operating Air Temp. on Radiator ..............60° C (150° F)
Maximum Ambient Temperature ................................50° C (140° F)

FUEL SYSTEM

Type of Fuel ...................................................................Natural Gas
Carburetor ...................................................................... Down Draft
Secondary Fuel Regulator .................................................Standard
Fuel Shut-off Solenoid ........................................................Standard
Operating Fuel Pressure .................... 11 in. - 14 in. Water Column

Fuel Consumption - ft

3

/hr (Natural Gas/LPV)

Exercise

25%

50%

75%

100%

Cycle

Load

Load

Load Load

140/56 371/149 713/287 994/400 1374/553

* Engine is not field convertible between natural gas and propane. Jet size and ignition timing are

factory set for the specific fuel.

ELECTRICAL SYSTEM

Battery Charge Alternator ............................................12V, 30 Amp
Static Battery Charger ....................................................12V, 2 Amp
Recommended Battery ................................................ 24F 525CCA
System Voltage .....................................................................12 Volts

Voltage Regulator
Type ................................................................................. Full Digital
Sensing ................................................................................ 3-phase
Regulation .............................................................................± 1/4%
Features ............................................ Built into H-100 Control Panel

V/F Adjustable, Adjustable

Voltage and Gain

Power Adjustment for Ambient Conditions
Temperature Deration
3% for every 10° C above °C ..................................................... 25
1.65% for every 10° above °F .................................................... 77
Altitude Deration
1% for every 100 m above m ................................................... 183
3% for every 1000 ft. above ft. ................................................. 600

Controller .............................................. H-panel

‹

‹

‹

6-1

Standby Generator Sets

Specifications

GenSpec007 Rev.

C 11/05