Pressure adjust potentiometer – Graco Inc. 1095 HI User Manual

Page 27

Advertising
background image

Pressure Control Board

311365G

27

Pressure Adjust Potentiometer

Removal

Relieve pressure; page 9. Wait 5 minutes
before servicing.

1. Remove four screws (38) and cover (96).

2. Disconnect potentiometer connector (C)

from motor control board (95).

3. Remove pressure control knob (34) with a

hex wrench.

4. Remove gasket (115), nut and

potentiometer (82) from control panel (68).

Installation

1. Install gasket (115), nut and potentiometer

(82) on control panel (68). Torque nut to
30-35 in-lb (3.38 - 3.95 N•m).

2. Install pressure control knob (34): Check

pressure control knob alignment to
potentiometer shaft. Turn shaft fully
clockwise and attach knob in full ON
position with a hex wrench.

3. Connect potentiometer connector (C) to

motor control board.

4. Install cover (96) with four screws (38).

96

38

ti13493a

C

95

ti12997a

ti7258a

34

68

82

115

82

ti12998a

68

82

115

82

ti12998a

ti7258a

34

C

95

ti12997a

96

38

ti13493a

Advertising