DVB4136 Direct Vent Gas Fireplace

20012322

FP580
INSTA VENT FREE
EB1 JUNCTION BOX
11/18/97

OUTSIDE

Electrical Box

FRONT OF UNIT

INSIDE

FRONT

OF UNIT

FP580

Fig. 9 EB-1 receptacle.

7. Connect the ground wire of the supply line to the

green screw of the socket assembly.

8. Refit the socket assembly back into the electrical

box and replace the cover plate. Secure the cable
with the clamp on the outside of the unit to prevent
strain on the connections.

9. The EB-1 electrical junction box is now ready to sup-

ply power to the FK12 or FK24 fan kits if fitted.