Dvb4136 direct vent gas fireplace, Pilot orifice conversion, Installation precautions – Majestic Appliances DVB4136 User Manual

Page 42: Conversion procedure, Burner orifice conversion

Advertising
background image

42

DVB4136 Direct Vent Gas Fireplace

20012322

3. Using a 1/2” open end wrench remove the orifices.

(Fig. 69)

4. To convert burner orifices, remove the orifices in the

manifold and replace with the proper orifice listed in
the table on Page 42.

5. To convert the air shutter, refer to the adjustment

listed in the table. NOTE: The air shutter on the
main burner is changed when converting to different
gases.

8. Reassemble the burner housing assembly, the

burner tube assembly and the fettle in reverse order.

Pilot Orifice Conversion

NOTE: It is not necessary to remove the pilot tube for
conversion.
1. Remove pilot hood by lifting up. (Fig. 70)
2. Remove pilot orifice with Allen wrench. (Fig. 71)
3. Install conversion pilot orifice.
4. Re-install pilot hood and be sure to align with index

tab. Installation is complete.

CO105a

DV360/580

Gas Conversion

Pilot

1/28/00 djt

Pilot Hood

Pilot

Bracket

CO105a

Fig. 70 Remove pilot hood.

CO106a

DV360/580

Gas Conversion

Pilot2

1/28/00 djt

Index Tab

Snap Ring

Allen Wrench

CO106a

Fig. 71 Remove pilot orifice.

�����
��������������
���������

Front Burner Orifice

(Refer to Table on

Page 42)

Rear Burner Orifice

(Refer to Table on

Page 42)

CO130

Fig. 69 Burner orifice replacement.

Manifold

Fuel Conversion Instructions

Honeywell Comfort Control Valve ONLY

WARNING: The conversion must only be
undertaken by a qualified, certified gas ap-
pliance installer.

Installation Precautions

Before proceeding, turn control knob on valve to OFF
and turn gas supply OFF. Turn OFF any electricity that
may be going to the appliance. CAUTION: Logs may
be hot!

Conversion Procedure

1. Open bottom grille to gain access to valve. Remove

glass door. (Refer to “Window Frame Assembly Re-
moval Section” Page 24, Fig. 47)

2. Remove logs if previously installed. CAUTION: Logs

may be hot!

3. Remove and replace plug on lower right hand side of

the valve; Red for LP and blue for NG. (Fig. 72)

FP1037

Honeywell

comfort valve

3/22/00 djt

LOCAL

REMOTE

O

N

PILO

T

OFF

LED

Motor Top Cap

Piezo Ignitor

LED

Local/

Remote Switch

Pilotstat

Knob

Plug

Antenna

FP1037

Fig. 72 Comfort control valve.

4. Remove motor top cap. Depress and turn center

plunger until arrow points to correct screw. Red for
LP and Blue for NG. NOTE: Plunger will “snap” into
NG position when arrow is close to blue screw. It will
not “snap” at LP (Red) position. (Fig. 73)

FP1037b

comfort valve

convert

3/6/01 djt

LOCAL

REMOTE

O

N

PILO

T

OFF

LED

Motor Top Cap

Center

Plunger

Blue - NG

Red - LP

FP1037b

Fig. 73 Depress and turn center plunger.

Burner Orifice Conversion

Refer to Burner Orifice Conversion on Page 40.

Advertising