Installation – Mega Catch Mini User Manual

Page 10

Advertising
background image

10

H

ORIZONTAL

E

XHAUST

T

HROUGH

W

ALL

I

NSTALLATION

:

Vent installation: install vent at clearances specified by the vent manufacturer.

A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces,

or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired,

the installation shall conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and

Equipment. Only use venting of L or PL type with an inside diameter of 3 or 4 inches (7.6 or 10.1 cm).
1. Choose a location for your stove that meets the requirements stated in this manual and allows

installation with the least amount of

interference to house framing, plumbing,

wiring, etc.

2. Install a non-combustible hearth pad

(where necessary).

3. Place the appliance 15” (37.5 cm) away

from the wall. If the stove is to be set on

a hearth pad, set the unit on it, and adjust

the leveling legs.

4. Locate the center of the exhaust pipe on

the stove. Extend that line to the wall.

Once you have located the center point on

the wall, refer to pellet vent manufacturer

installation instructions for correct hole size

and clearance to combustibles.

5. Install the wall thimble as per the

instructions written on the thimble. Maintain

an effective vapour barrier in accordance

Figure 10: Straight through wall Installation.

Non-combustible

floor protection.

Existing floor

(combustible)

6"

(15 cm)

4"

(10 cm)

Wall

thimble

Rodent

mesh cap

45°

elbow

12"

(30.5 cm)

Figure 9: Corner Installation.

Installation

C

ORNER

T

HROUGH

W

ALL

I

NSTALLATION

:

3" (75mm)

3"

(75mm)

Wall thimble

manufactured

by pellet vent

manufacturer.