Installation

Exhaust Tube

3" (75mm) or 4" (100mm) "PL" or "L" vent

Wall Thimble

45° Elbow with screen or

Termination Cap

High Temperature RTV

Silicone Required

Fresh Air Intake Tube

Figure 11: Venting to use with straight through wall Installation.

with local building codes.

6. Install a length of 3” (75 mm)

or 4” (100 mm) vent pipe into

the wall thimble. The pipe

should install easily into the

thimble.

7. Connect the exhaust vent

pipe to the exhaust pipe on

the stove. Seal the connection

with

high

temperature

silicone.

8. Push the stove straight back,

leaving a minimum of 4” (10

cm) clearance from the back

of the stove to the wall. Seal

the vent pipe to the thimble

with

high

temperature

silicone.

9. The pipe must extend at least

12” (30 cm) away from the

building. If necessary, bring

another length of pipe (PL type) to the outside of the home to connect to the first section. Do not

forget to place high temperature silicone around the pipe that passes through the thimble.

10. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The

stainless steel cap termination manufactured by the vent manufacturer is recommended. However,

when the vent terminates several feet above ground level and there are no trees, plants, etc. within

several feet, a 45° elbow can be used as termination. The elbow must be turned down to prevent

rain from entering.

NOTE:

• Some horizontal through wall installations may require a “T” and 3 to 5 feet (91 to 152 cm) of vertical

pipe outside the building to help naturally draft in the unit.

• This may be required if a proper burn cannot be maintained, after the stove has been tested and the

airflow set.

• This is due to the back pressure in the exhaust caused by airflow around the structure.

• All sections of pipe must have three (3) screws evenly spaced and all horizontal and vertical vent

sections located within the house must have a bead of high temperature silicone installed on the male

end of the pipe before installation to create a gas tight seal.

T

HROUGH

W

ALL

W

ITH

V

ERTICAL

R

ISE

AND

H

ORIZONTAL

T

ERMINATION

I

NSTALLATION

- F

REESTANDING

:

A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel

termination hood).

Figure 12 is the recommended installation set up.

Figure 13 is the installation to use if there is a concrete or retaining wall in line with exhaust vent on

a pellet stove. The termination must be 12” (30 cm) from the outside wall and 12” (30 cm) above the

ground.