Regarding the lamp (continued), Resetting the lamp timer – Marantz VP4001 User Manual

Page 57

Advertising
background image

56

Regarding the Lamp (Continued)

4

5

6

1

2

Info

AC socket

Securing screws

Handle

ENTER button

MENU button

R button

Info

2

1

ASP

ECT

ENT

ER

INPU

T

MEN

U

INPU

T

STAN

DBY

/ON

LAM

P

TEM

P.

ASPECT

ENTER

INPUT

MENU

INPUT

STANDBY/ON

LAMP

TEMP.

/ I STANDBY/

ON button

Connect the power cord.

• Plug the power cord into the AC socket

of the projector.

Reset the lamp timer.

• While simultaneously holding down

MENU,

ENTER and R on the projec-

tor, press / I STANDBY/ON on the pro-
jector.

• “LAMP 0000H” is displayed, indicating

that the lamp timer is reset.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

• Make sure to reset the lamp timer only when

replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.

Remove the lamp unit.

• Loosen the securing screws from the

lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.

Insert the new lamp unit.

• Press the lamp unit firmly into the lamp

unit compartment. Fasten the securing
screws.

Replace the lamp unit cover.

• Align the tab on the lamp unit cover (q)

and place it while pressing the tab (w)
to close it. Then tighten the user service
screw to secure the lamp unit cover.

• If the lamp unit and lamp unit cover are

not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.

06.7.19, 4:29 PM

Page 56

Advertising