OM-867 Page 5

SECTION 5 – MAINTENANCE & TROUBLESHOOTING

WARNING

ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Turn Off welding power source, and disconnect
input power before inspecting, maintaining, or
servicing. Stop engine on welding generator.

HOT PARTS can cause severe burns.

Allow cooling period before maintaining or servicing.

Maintenance and troubleshooting to be performed only
by qualified persons.

swarn8.1* 10/91

5-1.

Routine Maintenance

See

Section

7

Replace

Unreadable

Labels

Turn Off all power before maintaining.

ST-084 121-A

3 Months

OR

Blow Out

Or

Vacuum

Inside

6 Months

– –

Tape Or

Replace
Cracked

Weld

Cable

– –

Clean

And

Tighten

Weld

Terminals

3-2

Figure 5-1. Maintenance Schedule

5-2.

Troubleshooting

READ SAFETY BLOCKS at start of
Section 5 before proceeding.

WARNING

Table 5-1. Welding Trouble

Trouble

Remedy

Section

Unit completely inoperative; no meter
display.

Be sure input power cord is plugged in and that receptacle is receiv-
ing input power.

3-2

Incorrect meter display.

Check weld cable, input power, and voltage sensing connections.

3-2

Turn off high frequency, if applicable.

3-2

No display on one meter only; other me-
ter works.

Check connections to meter module; tighten or clean if necessary.

– –

Check and replace meter module if necessary.

– –

Have Factory Authorized Service Station/Service Distributor check
digital meter board PC1.

– –

Erratic meter display.

Check connections to meter shunt; tighten or clean if necessary.

– –

Meters do not hold display with Std./Hold
switch in Hold position.

Place switch in Std. position when welding amperage is below re-
quired minimum.

Figure 4-2

Have Factory Authorized Service Station/Service Distributor check
digital meter board PC1.

– –