23

CAUTION

M

AINTENANCE

Oven Door

Do not place excessive weight on or stand on an open
oven door. This could cause the range to tip over, break
the door, or injure the user.

Oven Window

To protect the oven door window:

1. Do not use abrasive cleaning agents such as steel wool

scouring pads or powdered cleansers as they may scratch
the glass.

2. Do not hit the glass with pots, pans, furniture, toys, or other

objects.

3. Do not close the oven door until the oven racks are in

place.

Scratching, hitting, jarring or stressing the glass may weaken
its structure causing an increased risk of breakage at a later
date.

Oven Light

Electrical Connection

Note: The oven door on a new range may feel “spongy”
when it is closed. This is normal and will decrease with use.

Leveling Legs

ANTI-TIP BRACKET

LEVELING LEG

LEVELING LEG

CAUTION

Be sure the anti-tip bracket secures one of the rear
leveling legs to the floor. This bracket prevents the range
from accidentally tipping.

The range should be leveled when installed. If
the range is not level, turn the plastic leveling
legs, located at each corner of the range, until
range is level.

ANTI-TIP BRACKET

CAUTION

• Disconnect power to oven before replacing light bulb.

• Allow oven to cool before replacing light bulb.

• Make sure bulb cover and bulb are cool before touching.

To replace oven light bulb:

1. When oven is cool, hold bulb cover

in place, then slide wire retainer
off cover. NOTE: Bulb cover
will fall if not held in place
while removing wire retainer.

2. Remove bulb cover and light

bulb.

3. Replace with a 40-watt appliance bulb.

4. Replace bulb cover and secure with wire retainer.

5. Reconnect power to range. Reset clock.

BULB COVER

WIRE

RETAINER

Appliances which require electrical power
are equipped with a three-prong
grounding plug
which must be plugged
directly into a properly grounded three-
hole 120 volt electrical outlet.

Always disconnect power to appliance before servicing.

The three-prong grounding plug offers protection against
shock hazards. DO NOT CUT OR REMOVE THE THIRD
GROUNDING PRONG FROM THE POWER CORD PLUG.

If an ungrounded, two-hole or other type electrical outlet is
encountered, it is the personal responsibility of the
appliance owner to have the outlet replaced with a
properly grounded three-hole electrical outlet.

8113P416-60B

9/28/04, 11:39 AM

24