C. DRYER ENCLOSURE REQUIREMENTS

Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of

twelve (12) inches above the dryer's outer top; except along the front of the dryer which may be closed if desired.

NOTE: Allowances must be made for opening the control door.

NOTE: Air considerations are important for proper and efficient operation.

Dryers may be positioned side wall to side wall. However, a 1/16" minimum allowance must be made for

opening and closing of the control door and the lint door. It is suggested that the dryer be positioned about two (2)

feet away from the nearest obstruction for ease of installation, maintenance, and service (to be measured from

the back guard). Refer to the illustration above for details.

X = 12" minimum, 24" suggested for ease of maintenance.