OM-880 Page 13

SECTION 4 – OPERATOR CONTROLS

SC-111 216-A

Circuit

Breaker CB5

Remote-14

Receptacle RC4

Circuit Breaker CB6

Output/Contactor

Switch S10

Current Control

Switch S11

Constant Voltage (CV)/

Constant Current(CC)

Switch S12

Prepunched Hole

For Securing

Key Chain

Remote-5

Receptacle RC3

Receptacle

Dust Cups

AC/DC Selector

Switch S1

CV-2 Control

Panel

Figure 4-1. CV-2 Panel Components

4-1.

CONSTANT VOLTAGE (CV)/CONSTANT
CURRENT (CC) SWITCH (Figure 4-1)

CC

CV

Placing this switch in the CC position causes the weld-
ing generator to provide weld output for processes re-
quiring a constant current output.

Placing this switch in the CV position causes the welding
generator to provide weld output for processes requiring
a constant voltage output.

IMPORTANT: When using the CV mode, place the AM-
PERE RANGES switch on the welding generator in the
maximum amperage range position.

4-2.

CURRENT CONTROL SWITCH (Figure 4-1)

PANEL

A
V

CURRENT
CONTROL

REMOTE

WARNING: ELECTRIC SHOCK can kill.

•

Do not touch live electrical parts.

•

Do not touch weld output terminals when
contactor is energized.

•

Do not touch welding wire or electrode and
work clamp at the same time.

If remote current or voltage control is desired, make
connections to either the REMOTE-5 or REMOTE-14
receptacle as instructed in Section 3-2 or 3-3. Place the
CURRENT CONTROL switch in the REMOTE position.