Assembler Directives

FAIL — Generate Error Message

MCUez HC12 Assembler

User’s Manual

MOTOROLA

Assembler Directives

179

8.16 FAIL — Generate Error Message

Syntax:

FAIL

<arg> | <string>

Description:

FAIL

directive operation depends on the operand specified. If

<arg> is in the range [500–$FFFFFFFF], the assembler
generates a warning message, including the line number and
argument of the directive.

Example:

The following code segment:

cpChar: MACRO

IFC "\1", ""

FAIL 200

MEXIT

ELSE

LDD \1

ENDIF

IFC "\2", ""

FAIL 600

ELSE

STD \2

ENDIF

ENDM

codeSec: SECTION

Start:

cpChar char1

Generates this error message:

>> in "Y:\DEMO\HC12A\cbe.asm", line 14, col 19, pos 242

IFC "\2", ""

FAIL 600

^

WARNING A2332: FAIL found

If <arg> is in the range [0–499], the assembler generates an
error message, including the line number and argument of the
directive. The assembler does not generate an object file.