Motorola HC12 User Manual

Page 223

Advertising
background image

Operating Procedures

Working with Relocatable Sections

MCUez HC12 Assembler

User’s Manual

MOTOROLA

Operating Procedures

223

The minimal linker parameter file will look like this:

LINK test.abs /* Name of the executable file generated. */

NAMES

test.o

/* Name of the object files in the application. */

END

SEGMENTS

/* READ_ONLY memory area. */

MY_ROM = READ_ONLY 0x0B00 TO 0x0BFF;

/* READ_WRITE memory area. */

MY_RAM = READ_WRITE 0x0800 TO 0x08FF;

END

PLACEMENT

/* Relocatable variable sections are allocated in MY_RAM. */

DEFAULT_RAM INTO MY_RAM;

/* Relocatable code and constant sections are allocated in MY_ROM. */

DEFAULT_ROM INTO MY_ROM;

END

INIT entry

/* Application entry point. */

VECTOR ADDRESS 0xFFFE entry /* Initialization of the reset vector. */

NOTE:

The programmer should ensure that the memory ranges specified in the
SEGMENT block are valid addresses for the MCU being used.

The module fibo.asm located in the demo directory is a small example of using
the relocatable sections in an application.