Muh-12nv, Model wiring diagram outdoor unit, Mc mf – MITSUBISHI ELECTRIC MSH-07NV User Manual

Page 20

Advertising
background image

20

MUH-12NV -

E2

MODEL WIRING DIAGRAM

OUTDOOR UNIT

21S4

SR61

CN661

CN721

X62

MC

MF

52C

4

3

WHT

RED

BLU

BLU

BLK

WHT

ORN

RED

BLK

WHT

RED

TRANS

R

S

C

C1

RED

BLK

12VDC

GRN/YLW

T

O

INDOOR UNIT

CONNECTING

TB

220-240V~

2

N

2
3
4

1

4

3

2

1

RT61

CN730

F61

BLK

BLK

X62

C65

TAB20

NR61

CN711

DEICER P.C.BOARD

1

WHT

IC881

3

SYMBOL

X62

21S4

52C

SYMBOL

MF

NR61

RT61

SYMBOL

C1

F61

MC

SR61

NAME

NAME

NAME

COMPRESSOR CAPACITOR

FUSE(2A)

COMPRESSOR<INNER THERMOSTAT>

SOLID STATE RELAY

OUTDOOR FAN MOTOR

VARISTOR

DEFROST THERMISTOR

REVERSING VALVE COIL RELAY

REVERSING VALVE COIL

CONTACTOR

SYMBOL

C65

IC881

TB

NAME

FAN MOTOR CAPACITOR

DC/DC CONVERTER

TERMINAL BLOCK

<INNER THERMOSTAT>

NOTE:1. Use copper conductors only.(For field wiring)

2. Since the indoor and outdoor unit connecting wires have polarity, connect them according to the numbers.
3. Symbols below indicate.

: Terminal block, : Connector

4. “

”show the terminals with a lock mechanism, so they cannot be removed when you pull

the lead wire.
Be sure to pull the wire by pushing the locking lever(projected part) of the terminal with a finger.

1.Slide the sleeve.

2.Pull the wire while

pushing the locking
lever.

OB207t-1qxp 25/9/97 8:52 PM Page 20