MITSUBISHI ELECTRIC MSH-07NV User Manual

Page 50

Advertising
background image

50

Measure the resistance between the terminals with a tester.
(Coil wiring temperature10°C ~ 30°C)

Compressor

Room
temperature
thermistor

10-2-2 Trouble criterion of main parts

Part name

Indoor coil
thermistor

Indoor fan
motor

Motor part

Sensor part

Outdoor fan
motor

Vane motor

Check method and criterion

Measure the resistance with a tester.
(Part temperature 10°C ~ 30°C)

Measure the resistance between the terminals with a tester.
(Coil wiring temperature –10°C ~ 40°C)

Measure the voltage Power ON.

Measure the resistance between the terminals with a tester.
(Coil wiring temperature –10°C ~ 40°C)

Measure the resistance between the terminals with a tester.
(Part temperature10°C ~ 30°C)

Figure

P

R

C

S

RED

BLK

WHT

MAIN

AUX.

07NV
09NV

Normal

8k

~ 20k

Abnormal

Opened or short-circuited

Normal

07NV

3.67~4.50

5.07~6.20

2.88~3.52

1.85~2.28

3.44~4.21

1.05~1.30

2.38~2.91

09NV

12NV

18NV

0.85~1.04

1.83~2.23

24NV

C-R

C-S

Normal

Abnormal

Opened or

short-circuited

18/24NV

280 ~ 303

176 ~ 192

240 ~ 261

WHT-BLK

BLK-RED

BRN-YLW

YLW-GRY

Normal

4.5 ~ 5.5V

Abnormal

Remain 0V or 5V

(When fan revolved one time)

0V

5V

0V

(Approx.)

Normal

Abnormal

Opened or

short-circuited

07/09NV

192~236

373~458

114 ~ 141

118 ~ 146

12NV

102 ~ 126

97.9 ~ 120

18NV

55.3 ~ 67.6

26.6 ~ 32.6

55.5 ~ 67.8

24NV

WHT-BLK

BLK-RED

BLK-YLW

YLW-RED

Normal

Abnormal

Opened or short-circuited

07/09/12NV 282 ~ 305

18/24NV

358 ~ 388

07/09/12NV

Abnormal

Opened or

short-circuited

ORN WHT

RED

BLK

MAIN

AUX.

P

WHT

RED

BLK

MAIN

AUX.

P

P

C

RED ORN WHT

YLW

BLK

MAIN

AUX.1AUX.2

313 ~ 336

5.13~6.28

MSH-07NV-

MSH-09NV-

MSH-12NV-

MSH-18NV-

MSH-24NV-

MSH-07NV-

MSH-09NV-

MSH-12NV-

MSH-18NV-

MSH-24NV-

MSH-18NV-

E3

E2

E2

E2

E2

E2

E1

E1

E1

E1

E1

Vane motor

ORN

BLU

YLW

INNER PROTECTOR

RED

PNK

ROTOR

P

FUSE

WHT

RED

BLK

MAIN

AUX.

12NV
18NV

24NV

Defrost
thermistor

Measure the resistance with a tester.
(Part temperature –10°C ~ 40°C)

Normal

5k

~ 60k

Abnormal

Opened or short-circuited