Performance data, Continued), Power is in the numbers – Miller Electric Trailblazer Pro 350 D User Manual

Page 3

Advertising
background image

3

VOLT/AMP CURVES

MINIMUM AND MAXIMUM - STICK MODE

AMPERES

VOL

TS

0

10

20

30

40

50

60

70

80

0

100

200

300

400

500

600

DUTY CYCLE CHART

WELD AMPERES

% DUTY CYCLE

0

10

20

30

40

50

60

70

80

90

100

100

150

200

250

300

350

400

DC Weld

AC Weld

VOLT/AMP CURVES

MINIMUM AND MAXIMUM - MIG MODE

AMPERES

0

100

200

300

400

500

600

0

10

20

30

40

50

60

70

80

VOL

TS

GENERATOR POWER CURVE

AC VOL

TS

AC AMPERES IN 240V MODE

AC AMPERES IN 120V MODE

300

250

200

150

100

50

0

150

125

100

75

50

25

0

0

10

20

30

40

50

60

70

80

90

0

20

40

60

80

100

120

140

160

180

SIMULTANEOUS WELDING

AND GENERATOR POWER

Weld

Current
(Amps)

Watts

120V 1P

Receptacle

Amps

240V 1P

Receptacle

Amps

0

100

150

200

300

350

100

90

80

62

25

10

50

45

40

31

12

5

12,000

11,000

9,500

7,500

3,000

1,000

12 kW

Performance Data

(continued)

All Trailblazers have 2 generators —
a 4-pole, 3-phase weld generator and a
strong power generator.

TRAILBLAZER ADVANTAGE: No interaction
between grinders, power tools, etc. and
the welding arc. Generator power is also
independent of weld control settings.

POWER IS IN THE NUMBERS

Tested and rated at higher temperatures, 104˚ F (40˚ C), to ensure consistent operation in all climates.

Patented generator control technology matches the generator’s output to engine horsepower providing maximum efficiency
and more weld output.

The generator is voltage regulated to provide strong power while keeping the voltage 120/240 volts. This increases
tool/motor performance and tool/motor life.

Stator

Rotor

Advertising