Performance data, Continued), Power is in the numbers – Miller Electric Trailblazer Pro 350 D User Manual

Page 3

Advertising
background image

3

VOLT/AMP CURVES

MINIMUM AND MAXIMUM - STICK MODE

AMPERES

VOL

TS

0

10

20

30

40

50

60

70

80

0

100

200

300

400

500

600

DUTY CYCLE CHART

WELD AMPERES

% DUTY CYCLE

0

10

20

30

40

50

60

70

80

90

100

100

150

200

250

300

350

400

DC Weld

AC Weld

VOLT/AMP CURVES

MINIMUM AND MAXIMUM - MIG MODE

AMPERES

0

100

200

300

400

500

600

0

10

20

30

40

50

60

70

80

VOL

TS

GENERATOR POWER CURVE

AC VOL

TS

AC AMPERES IN 240V MODE

AC AMPERES IN 120V MODE

300

250

200

150

100

50

0

150

125

100

75

50

25

0

0

10

20

30

40

50

60

70

80

90

0

20

40

60

80

100

120

140

160

180

SIMULTANEOUS WELDING

AND GENERATOR POWER

Weld

Current
(Amps)

Watts

120V 1P

Receptacle

Amps

240V 1P

Receptacle

Amps

0

100

150

200

300

350

100

90

80

62

25

10

50

45

40

31

12

5

12,000

11,000

9,500

7,500

3,000

1,000

12 kW

Performance Data

(continued)

All Trailblazers have 2 generators —
a 4-pole, 3-phase weld generator and a
strong power generator.

TRAILBLAZER ADVANTAGE: No interaction
between grinders, power tools, etc. and
the welding arc. Generator power is also
independent of weld control settings.

POWER IS IN THE NUMBERS

•

Tested and rated at higher temperatures, 104˚ F (40˚ C), to ensure consistent operation in all climates.

•

Patented generator control technology matches the generator’s output to engine horsepower providing maximum efficiency
and more weld output.

•

The generator is voltage regulated to provide strong power while keeping the voltage 120/240 volts. This increases
tool/motor performance and tool/motor life.

Stator

Rotor

Advertising