OM-884 Page 14

2-10. Arc Failure Light Connections

S-0292

.

Arc Failure light on robot inter-
face front panel turns on and off
by a signal from robot control
unit. Obtain proper length of 18
gauge/2-conductor cord for
this connection.

For robot control units when 24 vdc
is used:

1

Route cord through strain
relief on right side panel of
robot interface, and make
proper connections to 1TL
and 1TM.

2

Route and connect remaining
end of cord to weld alarm
terminal and ground
connection at the robot control
unit.

3

Connect +24 vdc to common
relay contact terminal.

For robot control units when 115 or
24 vac, or 24 vdc is used:

1

Route cord through strain
relief on right side panel of
robot interface, and make
proper connections to 1TL
and 1TM.

2

Obtain a 115 or 24 vac, or 24
vdc isolation relay CR1, and
install into robot control.

3

Route and connect remaining
end of cord to one side of the
normally-open robot control
relay contact and ground.

4

Connect +24 vdc to remaining
side of normally-open robot
control relay contact.

5

Connect a lead from one side
of robot control coil to weld
alarm terminal.

6

Connect proper voltage
source (115 vac, 24 vac, or 24
vdc) between common
terminal and remaining side of
robot control relay coil.

Tools Needed:

CR

1TL

+24VDC

Common Terminal

If So Equipped

Weld Alarm Terminal

If So Equipped

1TM

Arc Failure

Indicator Light

Robot Control Unit

Robot Interface

Robot Control Unit

Common Terminal

If So Equipped

Weld Alarm Terminal

If So Equipped

To Voltage Source

(115VAC, 24VAC, 24VDC)

Isolation Relay CR

Robot Control Unit

Robot Interface

1TL

1TM

Arc Failure

Indicator Light

+24VDC

Signal

Relay

CR

Signal

Relay

Isolation Relay CR