4. display board pc4 meter check – Miller Electric A.B.B. Robot Interface Gas Control Hub And Spindle User Manual

Page 28

Advertising
background image

OM-884 Page 24

REAR VIEW OF DISPLAY BOARD PC4

Input Command For

Wire Speed IPM Meter

0.8V = 800 IPM

Input Command For

Volts Meter –0.5V = 50V

Power Supply For Wire
Speed IPM Meter 5VDC

Power Supply For

Volts Meter And

Ammeter 5VDC

5-4.

Display Board PC4 Meter Check

Ref. ST-117 838-B / Ref. ST-119 647-C

Check points are provided on display
board PC4 for checking power supply and
input command to meters.

To make checks at display board, open
front access door.

1

Display Board PC4

2

Meter

CB1 protects the wire feed motor from
overload. If CB1 opens, the wire feed mo-

tor stops. Check for jammed wire, binding
drive gear, or misaligned drive rolls. Cor-
rect problem.

Allow cooling period and manually reset
breaker.

1

2

Receptacle RC20

Receptacle RC24

Advertising