OM-1572 Page 8

Figure 5-2. Checking Detector Pins And Checking/Replacing Shield Cup, Tip, And Electrode

5-3.

Troubleshooting

ELECTRIC SHOCK can kill.

•

Do not touch live electrical parts.

•

Turn Off power source, and disconnect input power
before inspecting, maintaining, or servicing.

HOT PARTS can cause severe burns.

•

Allow cooling period before maintaining or servicing.

Troubleshooting to be performed only by qualified
persons.

WARNING

swarn8.1* 2/93

Table 5-1. Cutting Trouble

Trouble

Remedy

Section

Sparks come out top of cut, or cut is not
clean.

Torch travel speed too fast; reduce travel speed.

Figure 4-2

Check torch tip and electrode, and replace if necessary.

5-2

Metal being cut is too thick; increase power source Thickness
control setting.

*

Arc goes out while cutting.

Make sure torch tip is touching metal while cutting.

Figure 4-2

Be sure work clamp is securely attached.

*

Arc goes on and off while cutting.

Torch travel speed is too slow; increase travel speed.

Figure 4-2

Check torch tip and electrode, and replace if necessary.

5-2

*See power source Owner’s Manual.