Transmission standard

Conforming to RS232C, 25pin D-SUB, connector used

Isolation method

Photo coupler isolation

Transmission distance

15m or less (shielded cable recommended)

Current consumption

DC 5V less than 200mA from base unit

Control flags and

data registers

M8121:Send wait flag

D8120:System configuration

M8122:Send flag

D8122:Remainder of send data

M8123:Receive completion

D8123:Amount of received data

M8161:8 bits/16 bits changeover

D8124:Header byte
D8125:Terminator byte

Performance specification

INSTALLATION NOTES AND USAGE

General specification

Ambient Temperature 0 to 55°C in operation -20 to 70 °C in storage

Ambient Humidity

35 to 85% RH (no condensation) in operation

Vibration Resistance

Conforming to JIS C 0911, 10 to 55Hz 0.5mm (max.2G),2 hours each in 3 axial

Impact Resistance

Conforming to JIS C 0912, 10 G three times each in 3 axial directions

Operating Ambience

Free from corrosive gas or excessive dust