Operation – Multiquip pOrtable generatOr (HOnda gX340 gasOline engine) gaC6HZ User Manual

Page 21

Advertising
background image

gaC-6HZ 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 21

OperatiOn

This section is intended to assist the operator with the initial

start-up of the portable generator. It is extremely important

that this section be read carefully before attempting to use

the generator in the field.

Before starting the engine

1. Be sure to disconnect all electrical loads from the

generator prior to starting the engine.

2.

NeveR start the engine with the main circuit breaker

in the

ON position. Always place circuit breaker (Figure 10)

in the

OFF position before starting.

Figure 10. Main Circuit Breaker (OFF)

3.

NeveR start the engine with the GFCI circuit breaker

in the

ON position. Always place circuit breaker (Figure

11) in the

OFF position before starting. engine

Figure 11. GFCI Circuit Breaker (OFF)

starting the engine

1. Place the engine fuel valve lever (Figure 12) in the

ON

position.

Figure 12. Engine Fuel Valve Lever (ON)

2. Place the choke lever (Figure 13) in the

ClOsed

position if starting a cold engine.

Figure 13. Choke Lever

3. Place the choke lever (Figure 13) in the

OpeN position

if starting a warm engine or the temperature is warm.

4. Place the generator's operation switch (Figure 14) in

the

ON position.

Figure 14. Operation Switch (ON)

5. Press the generator's pushbutton start switch (Figure

15) and listen for the engine to start. If the battery is

not installed proceed to step 6.

Figure 15. Start Pushbutton Switch

6. Grasp the starter grip (Figure 16) and slowly pull it out.

The resistance becomes the hardest at a certain

position, corresponding to the compression point. Pull

the starter grip briskly and smoothly for starting.

Figure 16. Starter Grip