gaC-6HZ 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 23

OperatiOn/sHutdOwn

13. Read voltmeter on front panel of generator (Figure 22)

and verify that 240 VAC is displayed. Using an external

voltmeter as shown in Figure 20, verify that 240 VAC

is present at the 240V twist-lock receptacle.

Figure 22. 240V Receptacle

14. Connecting of loads (power tools, lighting ect.) to the

generator receptacles can now be done.

stopping the engine (Normal shutdown)

1. Place main circuit breaker (Figure 23) in the

OFF

position.

Figure 23. Main Circuit Breaker (OFF)

NOTICE

When using a combination of dual receptacles, total

load should not exceed the rated capacity of the

generator.

2. Place GFCI circuit breaker (Figure 24) in the

OFF

positing.

Figure 24. GFCI Circuit Breaker (OFF)

3. Place idle control switch (Figure 25) in the

OFF position.

Figure 25. Idle Control switch (OFF)

4. Let engine run at idle with no load for 2-3 minutes.
5. To shut-down the engine, place the generator's

operation switch (Figure 26) in the

OFF position).

Figure 26. Operation Switch (OFF)

6. Place engine fuel valve lever (Figure 27) in the

OFF

position.

Figure 27. Engine Fuel Valve Lever (OFF)

7. Remove all loads from the generator.

emergency shutdown

8. Place operation switch (Figure 26) in the

OFF position