OperatiOn

7. If the engine has started, slowly return the choke lever

(Figure 13) to the

OpeN position. If the engine has not

started repeat steps 1 through 8.

8. Before the generator is placed into operation, run the

engine for 3-5 minutes. Check for abnormal smells,

fuel leaks, and noises that would associate with lose

components.

9. Place idle control switch (Figure 17) in the

OFF (down)

position. This will allow the engine speed to run at about

3600 RPM's.

Figure 17. Idle Control Switch (OFF)

Figure 18. Idle Control switch (ON)

NOTICE

dO NOT pull the starter rope all the way to the end.
dO NOT release the starter rope after pulling. Allow it

to rewind as soon as possible..

NOTICE

Placing the idle control switch in the

OFF position

(Figure 17) allows the engine to operate at a maximum

speed of about 3600 RPM's.
When the idle control switch (Figure 18) is placed in the

up position (

ON), the generator will run at idle speed

(2200 RPM's) until a load is applied, at that time the

engine speed will increase to 3600 RPM's as long as

a load is being applied.
When the load is not in use, the engine speed will drop

back to the idle mode after about 3 seconds.

10. Place main circuit breaker (Figure 19) in the

ON

position.

Figure 19. Main Circuit Breaker (ON)

11. Place GFCI circuit breaker (Figure 20) in the

ON

position.

Figure 20. GFCI Circuit Breaker (ON)

12. Read voltmeter on front panel of generator (Figure 21)

and verify that 120 VAC is displayed. Using an external

voltmeter as shown in Figure 21, verify that 120 VAC

is present at the 120V twist-lock and GFCI duplex

receptacles. .

Figure 21. 120V/GFCI Receptacles