Ss38 direct vent gas stove – Monessen Hearth SS38 User Manual
Page 15

15
46D0232
SS38 Direct Vent Gas Stove
HORIZONTAL TERMINATION
CONFIGURATIONS
Figures 15 through 17 show different configurations for
venting with horizontal termination. Each figure includes
a chart with vertical minimum/maximum and horizontal
maximum dimensions which must be met. All horizontal
terminations require a 1/4" rise per 12" of horizontal run.
NOTE: Add 1/4" rise per 12" horizontal length of pipe.
VENTING INSTALLATION
Table 1 - Horizontal Venting
Vertical (V) Minimum
Horizontal (H) Maximum
5'
30"
6'
8'
8'
20'
NOTE: This configuration is for use with corner
installation also.
Figure 15 -
Horizontal Termination Configuration for Rigid
Venting Using One 90° Elbow
HOT
H
V
ST1105
horz term 1 elbow
ST1105
Table 2 - Horizontal Venting with Two (2) 90° Elbows
Vertical (V) Horizontal (H)
Horizontal (H) +
Minimum
Horizontal (H
1
) Max.
7'
4' Max.
8'
8'
6' Max.
12'
9'
8' Min.
20'
20'
8' Max.
20'
NOTE: Add 1/4" rise per 12" horizontal length of pipe.
H
V
H
1
ST1106
horiz term 2 elbows
Figure 16 -
Horizontal Termination Configuration for Rigid
Venting Using Two 90° Elbows
ST1106