air shutter open

AIR SHUTTER ADjUSTMENT (NATURAL GAS ONLY)

ADjUSTING THE AIR SHUTTER

The venturi of the burner is equipped with an air shutter. The opening of the venturi has been set at
1/4" for Natural Gas and fully open for Propane installation at sea level. Natural Gas Models may be
adjusted for high altitude as follows:

To increase air mixture, push up the adjustment rod located beneath the stove. This opens the
shutter more and will stop or minimize sooting. Figure 46

To decrease air mixture, pull down the adjustment rod located beneath the stove. This closes the
shutter. Flames will be more yellow. Figure 47

Figure 47 -
Pull Adjustment Rod Down to Close Air Shutter

Air Shutter

Adjustment
Rod

Figure 46 -
Push Adjustment Rod Up to
Open Air Shutter